As reported by CISA in ICSA-26-328-02, Schneider Electric has disclosed a locally exploitable vulnerability in its EcoStruxure Power Build Rapsody software — a tool used by electrical engineers to design single-line diagrams and generate bills of materials for switchboard assemblies. The flaw, tracked as CVE-2026-119055, is a use-after-free condition (CWE-416) that can be triggered when a user opens a specially crafted malicious SSD file, potentially resulting in arbitrary code execution on the host system.
| Field | Details |
|---|---|
| CVE | CVE-2026-119055 |
| CVSS v3 | 5.3 (Medium) |
| CWE | CWE-416 (Use After Free) |
| Vendor | Schneider Electric |
| Affected Product | EcoStruxure Power Build Rapsody (multiple locale-specific versions) |
| Patch Available | Yes — fixed versions released per locale |
| Active Exploitation | Not confirmed in the wild at time of publication |
Why This Matters
While the CVSS score of 5.3 places this in the medium-severity band, defenders should not be lulled by the number. The vulnerability requires local access and user interaction — specifically, social engineering a user into opening a malicious SSD file — but in operational technology (OT) environments, that attack path is more viable than it appears. Engineering workstations are often shared, lightly monitored, and run software that processes project files received from contractors, vendors, or partners via email or USB media.
The affected product is deployed across the Energy, Critical Manufacturing, and Commercial Facilities sectors — industries where a compromised engineering workstation can serve as a beachhead into the broader OT network. A use-after-free leading to arbitrary code execution on a machine that designs electrical switchboard configurations could enable attackers to pivot laterally, exfiltrate project data, or tamper with designs that later get deployed in physical infrastructure.
Beyond the Score: The SSD File Attack Surface
SSD files are the native project format for Rapsody. In practice, these files circulate freely between engineering teams, subcontractors, and clients during switchboard design and procurement. There is typically no file-integrity validation or sandboxing applied to their ingestion. This makes the SSD file format an attractive vector for targeted attacks against engineering staff — a pattern we have observed repeatedly with similar OT design tools from other vendors.
The key takeaway: file-format vulnerabilities in engineering software are a documented and recurring attack vector in OT. The CVSS score reflects the technical difficulty of exploitation, not the business risk of a successful compromise.
Shield53 Recommendations
Broader Implications
This advisory is a reminder that OT security extends well beyond PLCs and SCADA systems. The engineering software used to design, configure, and procure physical infrastructure is itself a critical attack surface. Vendors and asset owners alike should treat design-file formats with the same scrutiny applied to any untrusted input. Schneider Electric acted responsibly by issuing a patch, but the persistent pattern of memory-corruption bugs in file-parsing routines across the OT software ecosystem suggests that secure-by-design principles have not yet penetrated engineering tool development.