As reported by CISA in ICSA-26-328-02, Schneider Electric has disclosed a locally exploitable vulnerability in its EcoStruxure Power Build Rapsody software — a tool used by electrical engineers to design single-line diagrams and generate bills of materials for switchboard assemblies. The flaw, tracked as CVE-2026-119055, is a use-after-free condition (CWE-416) that can be triggered when a user opens a specially crafted malicious SSD file, potentially resulting in arbitrary code execution on the host system.

Security Impact: As reported by CISA in ICSA-26-328-02, Schneider Electric has disclosed a locally exploitable vulnerability in its EcoStruxure Power Build Rapsody software — a tool used by electrical engineers to design single-line diagrams and generate bills of materials for switchboard assemblies.

FieldDetails
CVECVE-2026-119055
CVSS v35.3 (Medium)
CWECWE-416 (Use After Free)
VendorSchneider Electric
Affected ProductEcoStruxure Power Build Rapsody (multiple locale-specific versions)
Patch AvailableYes — fixed versions released per locale
Active ExploitationNot confirmed in the wild at time of publication

Why This Matters

While the CVSS score of 5.3 places this in the medium-severity band, defenders should not be lulled by the number. The vulnerability requires local access and user interaction — specifically, social engineering a user into opening a malicious SSD file — but in operational technology (OT) environments, that attack path is more viable than it appears. Engineering workstations are often shared, lightly monitored, and run software that processes project files received from contractors, vendors, or partners via email or USB media.

The affected product is deployed across the Energy, Critical Manufacturing, and Commercial Facilities sectors — industries where a compromised engineering workstation can serve as a beachhead into the broader OT network. A use-after-free leading to arbitrary code execution on a machine that designs electrical switchboard configurations could enable attackers to pivot laterally, exfiltrate project data, or tamper with designs that later get deployed in physical infrastructure.

Beyond the Score: The SSD File Attack Surface

SSD files are the native project format for Rapsody. In practice, these files circulate freely between engineering teams, subcontractors, and clients during switchboard design and procurement. There is typically no file-integrity validation or sandboxing applied to their ingestion. This makes the SSD file format an attractive vector for targeted attacks against engineering staff — a pattern we have observed repeatedly with similar OT design tools from other vendors.

The key takeaway: file-format vulnerabilities in engineering software are a documented and recurring attack vector in OT. The CVSS score reflects the technical difficulty of exploitation, not the business risk of a successful compromise.

Shield53 Recommendations

Shield53 Recommendations
Patch immediately. Upgrade to the fixed version corresponding to your locale build: FR V2.9.12.0101, ESP V2.9.5.0000, PT V2.9.7.0000, BEL(FR) V2.9.8.0000, BEL(EN) V2.9.3.0000, INT(EN) V2.9.4.0000, INT(FR) V2.9.6.0000, or NL V2.9.6.0000. Downloads are available via the Schneider Electric product portal.
Restrict SSD file origin. Implement allowlisting for SSD files received via email or external media. Reject unsolicited project files and require a known sender verification process.
Deploy application allowlisting. Use Windows AppLocker or WDAC to prevent unexpected executable code from launching on engineering workstations, limiting the blast radius of a successful exploit.
Isolate engineering workstations. Ensure machines running Rapsody are not directly internet-connected and are segmented from both the corporate IT network and the OT control network. Use jump hosts for any necessary file transfer.
Monitor for anomalous process activity. Enable EDR coverage on engineering workstations. Create detection rules for unexpected child processes spawned by the Rapsody executable, particularly PowerShell, cmd.exe, or any compiled binaries launched from temp directories.
Educate engineering staff. Include file-format phishing scenarios in security awareness training tailored to OT engineering teams. The social engineering vector here is not generic phishing — it is a targeted SSD file disguised as a legitimate project package.

Broader Implications

This advisory is a reminder that OT security extends well beyond PLCs and SCADA systems. The engineering software used to design, configure, and procure physical infrastructure is itself a critical attack surface. Vendors and asset owners alike should treat design-file formats with the same scrutiny applied to any untrusted input. Schneider Electric acted responsibly by issuing a patch, but the persistent pattern of memory-corruption bugs in file-parsing routines across the OT software ecosystem suggests that secure-by-design principles have not yet penetrated engineering tool development.

For CISOs in critical infrastructure, the question is not whether this vulnerability will be exploited — it is whether your engineering workstations are prepared for the next one.